Projects
Acid vapours extraction and VOCs treatment plants
GGE realised two extraction systems for a well-known pharmaceutical company located near Modena (Italy). The purpose of the plants is to extract acidic vapours and VOCs generated by the reactors in which the chemical synthesis processes for the transformation of active pharmaceutical ingredients (APIs) take place.
The acid vapours treatment plant is equipped with a PVC centrifugal fan in Atex Ex II 3G execution: this generates a negative pressure, which extracts the vapours through Aisi 304 stainless steel hoods located near the reactor.
The air thus intake, charged with acidic vapours, flows into a washing tower (scrubber): the air enters at the base of the scrubber and passes through a bed of filling bodies. At the same time, a stream of water flows countercurrently, sprayed at the top of the scrubber. The bed of filling bodies creates a high contact surface between air and water and, in this transition, the pollutant is absorbed by the water. A stage of droplet separators prevents entrainment to the outside of the tower.
The extraction system for VOCs treatment is equipped with two filter units. The exhaled air from the reactors is extracted by hoods, suction walls and Miniel suction arms, all made of Aisi 304 stainless steel.
A centrifugal fan in Atex Ex II 3GD execution conveys the air into the first filtering unit Airsol Pol, also in Atex Ex II 3GD execution: this filter has the task of eliminating any dust present in the flow, which could limit the efficiency of the subsequent active carbon filtering stage. Airsol Pol filters dust through 3 filtration stages: 2 acrylic prefilters, 2 metal prefilters and 2 high-efficiency pocket filters.
As the last stage, the air passes inside the CARB C activated carbon filter unit, 3 m high and 2.2 m in diameter, with a structure made entirely of Aisi 304 stainless steel. CARB C contains a bed of activated carbon approximately 1800 kg and 80 cm thick: the activated carbon adsorbs the solvents in the air, which is thus purified and expelled into the atmosphere.
The CARB C filter is also equipped with a flooding fire prevention system: a temperature sensor, above a certain limit, activates the flooding of the unit.
The two control panels that manage the acid vapours extraction and VOCs treatment plants were built in accordance with Industry 4.0 standards: plants start-up and shutdown are managed by inverters, HMI panels, PLCs and softwares for the transmission of operating data and alarms via Modbus TCP/IP protocol.